        <lastBuildDate>Sat, 18 Apr 2026 23:08:00 +0800</lastBuildDate><atom:link href="https://www.knightli.com/es/tags/hr630x/index.xml" rel="self" type="application/rss+xml" /><item>
        <title>Notas de Lenovo HR630x / HR650x: LGA3647, 8259CL, Optane y errores comunes</title>
        <link>https://www.knightli.com/es/2026/04/18/lenovo-hr630x-hr650x-lga3647-homelab-notes/</link>
        <pubDate>Sat, 18 Apr 2026 23:08:00 +0800</pubDate>
        
        <guid>https://www.knightli.com/es/2026/04/18/lenovo-hr630x-hr650x-lga3647-homelab-notes/</guid>
        <description>&lt;p&gt;Los servidores LGA3647 de segunda mano se han vuelto cada vez más asequibles, y las máquinas Lenovo &lt;code&gt;HR630x&lt;/code&gt;/&lt;code&gt;HR650x&lt;/code&gt; retiradas de implementaciones en la nube ahora están entrando en la escena de búsqueda de gangas en los laboratorios domésticos. Su atractivo es obvio: Xeon Scalable de doble socket, muchas ranuras de memoria, redes OCP, backplanes U.2, administración de IPMI, además de la ventaja de precio de algunas CPU Xeon OEM de segunda generación y Optane PMem. Es fácil imaginar una &amp;ldquo;caja de computación de clase de mil yuanes&amp;rdquo; a partir de estas partes.&lt;/p&gt;
&lt;p&gt;Pero estas máquinas no son como actualizar una PC de escritorio normal. Antes de comprar uno, vale la pena considerar varios obstáculos: versiones de la placa base, generación de CPU, límites de potencia de VRM, compatibilidad de memoria, fuentes de alimentación patentadas, ruido del ventilador, elevadores raros, placas posteriores y bandejas de disco duro, contraseñas de BMC y si el BIOS es lo suficientemente nuevo.&lt;/p&gt;
&lt;p&gt;Esta publicación reorganiza las notas de dos informes de compilación. El objetivo no es reproducir una construcción exacta, sino aclarar las compensaciones y trampas en torno a la ruta &lt;code&gt;HR630x&lt;/code&gt;/&lt;code&gt;HR650x&lt;/code&gt;.&lt;/p&gt;
&lt;h2 id=&#34;posicionamiento-de-la-plataforma&#34;&gt;Posicionamiento de la plataforma
&lt;/h2&gt;&lt;p&gt;&lt;code&gt;HR630x&lt;/code&gt; y &lt;code&gt;HR650x&lt;/code&gt; son plataformas de servidor LGA3647 de hiperescala de Lenovo. En términos simples:&lt;/p&gt;
&lt;ul&gt;
&lt;li&gt;&lt;code&gt;HR630x&lt;/code&gt; es una máquina de 1U, más delgada y con más restricciones de expansión.&lt;/li&gt;
&lt;li&gt;&lt;code&gt;HR650x&lt;/code&gt; es una máquina de 2U, con más espacio para expansión, refrigeración e instalación.&lt;/li&gt;
&lt;li&gt;Las dos plataformas comparten muchas referencias a nivel de junta directiva, por lo que ambas cuentan con mucha experiencia práctica.&lt;/li&gt;
&lt;li&gt;Estas máquinas suelen ser unidades retiradas de la nube: baratas, pero no siempre completas.&lt;/li&gt;
&lt;/ul&gt;
&lt;p&gt;Si desea colocar un servidor silencioso y de bajo consumo junto a su escritorio, esta no es la mejor opción. Si su objetivo es el acceso de bajo costo a Xeons duales, más PCIe, muchas ranuras de memoria y administración remota, son atractivos.&lt;/p&gt;
&lt;h2 id=&#34;verifique-primero-que-esté-completo&#34;&gt;Verifique primero que esté completo
&lt;/h2&gt;&lt;p&gt;A la hora de comprar este tipo de sistema básico, no te fijes sólo en el precio base. El costo real depende de lo que falta.&lt;/p&gt;
&lt;p&gt;Verifique estos elementos cuidadosamente:&lt;/p&gt;
&lt;ul&gt;
&lt;li&gt;Si se incluyen ambos disipadores de calor de la CPU.&lt;/li&gt;
&lt;li&gt;Si todos los fans están presentes.&lt;/li&gt;
&lt;li&gt;Si el número de fuentes de alimentación y la potencia en vatios son suficientes.&lt;/li&gt;
&lt;li&gt;Si se incluye una placa posterior de unidad U.2/2,5 pulgadas.&lt;/li&gt;
&lt;li&gt;Si se incluyen los cables de transmisión.&lt;/li&gt;
&lt;li&gt;Si se incluyen bandejas de unidades.&lt;/li&gt;
&lt;li&gt;Si se incluyen elevadores PCIe.&lt;/li&gt;
&lt;li&gt;Si se incluye la NIC de OCP.&lt;/li&gt;
&lt;li&gt;Si la placa base es de versión 24-DIMM o 16-DIMM.&lt;/li&gt;
&lt;/ul&gt;
&lt;p&gt;Algunas máquinas parecen baratas, pero si carecen de soportes verticales, bandejas, placas posteriores o fuentes de alimentación patentadas, la búsqueda de piezas posteriores puede resultar más dolorosa que la compra original. Esto es especialmente cierto para los soportes verticales, las placas posteriores U.2 y las bandejas de unidades &lt;code&gt;HR650x&lt;/code&gt;: no siempre son fáciles de encontrar en el mercado usado y los precios no siempre son amigables.&lt;/p&gt;
&lt;h2 id=&#34;cpu-por-qué-el-económico-8259cl-necesita-trabajo-adicional&#34;&gt;CPU: Por qué el económico 8259CL necesita trabajo adicional
&lt;/h2&gt;&lt;p&gt;Una ruta común orientada al valor es utilizar una CPU OEM escalable Xeon de segunda generación, como la &amp;ldquo;Platinum 8259CL&amp;rdquo;. Es barato, tiene muchos núcleos e hilos y, como CPU de plataforma de segunda generación, puede funcionar con memoria persistente Optane de primera generación.&lt;/p&gt;
&lt;p&gt;Pero las piezas baratas suelen tener una razón. El &amp;ldquo;8259CL&amp;rdquo; es un modelo OEM con un TDP de aproximadamente &amp;ldquo;210W&amp;rdquo;, ligeramente por encima del límite de &amp;ldquo;205W&amp;rdquo; que muchas plataformas esperan de forma predeterminada. Esa diferencia parece pequeña, pero en algunas placas base puede impedir que el sistema se inicie a menos que modifique el límite actual o relacionado con la energía del controlador VRM.
El método común es utilizar una herramienta USB-I2C como &amp;ldquo;MCP2221A&amp;rdquo;, conectarla a la interfaz VRM I2C de la placa base y escribir un nuevo límite en controladores VRM como &amp;ldquo;PXE1610C&amp;rdquo;. En los casos de referencia, el formulario de comando para &lt;code&gt;HR630x&lt;/code&gt;/&lt;code&gt;HR650x&lt;/code&gt; tiene este aspecto:&lt;/p&gt;
&lt;div class=&#34;highlight&#34;&gt;&lt;div class=&#34;chroma&#34;&gt;
&lt;table class=&#34;lntable&#34;&gt;&lt;tr&gt;&lt;td class=&#34;lntd&#34;&gt;
&lt;pre tabindex=&#34;0&#34; class=&#34;chroma&#34;&gt;&lt;code&gt;&lt;span class=&#34;lnt&#34;&gt;1
&lt;/span&gt;&lt;/code&gt;&lt;/pre&gt;&lt;/td&gt;
&lt;td class=&#34;lntd&#34;&gt;
&lt;pre tabindex=&#34;0&#34; class=&#34;chroma&#34;&gt;&lt;code class=&#34;language-text&#34; data-lang=&#34;text&#34;&gt;&lt;span class=&#34;line&#34;&gt;&lt;span class=&#34;cl&#34;&gt;ModTool.exe -PXE1610C 74 76
&lt;/span&gt;&lt;/span&gt;&lt;/code&gt;&lt;/pre&gt;&lt;/td&gt;&lt;/tr&gt;&lt;/table&gt;
&lt;/div&gt;
&lt;/div&gt;&lt;p&gt;La cuestión es no copiar el comando a ciegas. Primero confirme el modelo VRM de su placa base, la ubicación del encabezado I2C, el orden de pines &lt;code&gt;SCL&lt;/code&gt;, &lt;code&gt;SDA&lt;/code&gt;, &lt;code&gt;GND&lt;/code&gt; y las direcciones. Cablearlo mal o utilizar el comando de plataforma incorrecto es más riesgoso que la propia CPU.&lt;/p&gt;
&lt;h2 id=&#34;prepare-una-cpu-de-arranque-en-buen-estado&#34;&gt;Prepare una CPU de arranque en buen estado
&lt;/h2&gt;&lt;p&gt;Si la máquina llega con un BIOS antiguo, o si la modificación del VRM aún no se ha realizado, la instalación directa de un &lt;code&gt;8259CL&lt;/code&gt; puede no producir ninguna visualización. En ese caso, un Xeon económico de primera generación como CPU de arranque puede facilitar mucho la resolución de problemas.&lt;/p&gt;
&lt;p&gt;Una CPU de arranque es útil para:&lt;/p&gt;
&lt;ul&gt;
&lt;li&gt;Entrar en BIOS y comprobar la versión.&lt;/li&gt;
&lt;li&gt;Actualización de BIOS y BMC.&lt;/li&gt;
&lt;li&gt;Confirmar que la placa base, la memoria, la fuente de alimentación y los ventiladores estén en buen estado.&lt;/li&gt;
&lt;li&gt;Excluyendo fallos básicos de hardware antes de modificar el VRM.&lt;/li&gt;
&lt;/ul&gt;
&lt;p&gt;Si el vendedor ya actualizó el BIOS y la máquina puede iniciarse directamente, es posible que no se necesite la CPU de inicio. Sin embargo, para los principiantes, reduce en gran medida la dificultad de depuración.&lt;/p&gt;
&lt;h2 id=&#34;optane-pmem-es-lo-más-destacado-de-esta-plataforma&#34;&gt;Optane PMem es lo más destacado de esta plataforma
&lt;/h2&gt;&lt;p&gt;Xeon Scalable de segunda generación admite la memoria persistente Intel Optane DC de primera generación, también conocida como &lt;code&gt;DCPMM&lt;/code&gt;/&lt;code&gt;PMem&lt;/code&gt;. Se instala en ranuras DIMM y se puede configurar en BIOS como modo de memoria o como almacenamiento en bloque persistente.&lt;/p&gt;
&lt;p&gt;Esta es una de las razones por las que las CPU como la &lt;code&gt;8259CL&lt;/code&gt; son atractivas: cuando los módulos DDR4 RDIMM / LRDIMM grandes se vuelven costosos, Optane PMem usado puede ser una forma económica de agregar capacidad.&lt;/p&gt;
&lt;p&gt;Sin embargo, Optane no es un reemplazo completo de la DRAM normal. Tenga en cuenta estos puntos:&lt;/p&gt;
&lt;ul&gt;
&lt;li&gt;Requiere un Xeon de segunda generación con soporte DCPMM.&lt;/li&gt;
&lt;li&gt;La BIOS debe admitir e identificar correctamente a Optane.&lt;/li&gt;
&lt;li&gt;Por lo general, todavía se requiere DRAM como caché o como nivel de memoria complementario.&lt;/li&gt;
&lt;li&gt;La colocación de ranuras y el emparejamiento de canales deben seguir el manual de Lenovo.&lt;/li&gt;
&lt;li&gt;El rendimiento se sitúa entre la DRAM y la SSD, por lo que no espere un comportamiento normal de la DRAM.&lt;/li&gt;
&lt;li&gt;Puedes crear espacios de nombres y usarlos como dispositivos de bloque como &lt;code&gt;/dev/pmem0&lt;/code&gt;.&lt;/li&gt;
&lt;/ul&gt;
&lt;p&gt;Si el objetivo es experimentar con memorias de alta capacidad y bajo costo, Optane es interesante. Si el objetivo es el ancho de banda de memoria máximo, es posible que una configuración Optane con un número bajo de canales no sea adecuada.&lt;/p&gt;
&lt;h2 id=&#34;versiones-y-compatibilidad-de-ranuras-de-memoria&#34;&gt;Versiones y compatibilidad de ranuras de memoria
&lt;/h2&gt;&lt;p&gt;&lt;code&gt;HR630x&lt;/code&gt; / &lt;code&gt;HR650x&lt;/code&gt; pueden venir en versiones de 24 DIMM y 16 DIMM. Antes de realizar el pedido, pídale al vendedor fotografías claras de la placa base en lugar de confiar en el título del anuncio.&lt;/p&gt;
&lt;p&gt;Para la memoria, es más seguro comprar la misma marca, frecuencia, capacidad y rango en un solo lote. Las notas de compilación de referencia mencionan el reconocimiento inestable al mezclar módulos y, en algunos casos, incluso el intercambio de posiciones de CPU o memoria afectó la memoria detectada.&lt;/p&gt;
&lt;p&gt;Reglas más seguras:&lt;/p&gt;
&lt;ul&gt;
&lt;li&gt;Seguir el orden de ocupación de espacios del manual oficial.&lt;/li&gt;
&lt;li&gt;Evite mezclar demasiadas marcas y especificaciones.&lt;/li&gt;
&lt;li&gt;Cuando no esté seguro, inicie primero con la configuración mínima.&lt;/li&gt;
&lt;li&gt;En plataformas de doble socket, verifique los canales de memoria conectados a cada CPU.&lt;/li&gt;
&lt;li&gt;Cuando utilice Optane, verifique nuevamente el emparejamiento de canales DRAM y PMem.&lt;/li&gt;
&lt;/ul&gt;
&lt;p&gt;La memoria del servidor no es &amp;ldquo;si cabe, arranca&amp;rdquo;. Cuanto mayor y más variada sea la capacidad, mayor será el costo de depuración.
Además, la memoria no se puede insertar al azar. La documentación oficial de Lenovo define el orden de ocupación de DIMM para el modo independiente. Antes de compilar, verifique las ranuras con el manual y luego expanda desde la configuración mínima de arranque. Esto es aún más importante con enchufes dobles, capacidad mixta, rango mixto u Optane PMem; un diseño incorrecto puede provocar que no se inicie, que falte memoria o que solo se detecten los canales bajo una CPU.&lt;/p&gt;
&lt;h2 id=&#34;no-subestimes-a-los-fans-y-al-ruido&#34;&gt;No subestimes a los fans y al ruido
&lt;/h2&gt;&lt;p&gt;Estas máquinas no fueron diseñadas para dormitorios u oficinas en el hogar. El &lt;code&gt;HR630x&lt;/code&gt; de 1U es especialmente obvio: las velocidades del ventilador son altas, el sonido es nítido y la política de arranque predeterminada puede ser muy conservadora.&lt;/p&gt;
&lt;p&gt;Según las notas de compilación, la velocidad predeterminada del ventilador es alta y se necesita control IPMI/CLI para reducir el ruido. Después del ajuste, el ruido en inactivo puede ser mucho mejor, pero bajo carga completa con dos CPU de alta potencia, el sistema aún necesita suficiente flujo de aire.&lt;/p&gt;
&lt;p&gt;Al sintonizar ventiladores, controle:&lt;/p&gt;
&lt;ul&gt;
&lt;li&gt;Temperatura de la CPU.&lt;/li&gt;
&lt;li&gt;Temperatura VRM.&lt;/li&gt;
&lt;li&gt;Temperatura PCH.&lt;/li&gt;
&lt;li&gt;Temperatura de la memoria.&lt;/li&gt;
&lt;li&gt;Temperatura de la fuente de alimentación.&lt;/li&gt;
&lt;li&gt;Temperaturas de entrada y salida.&lt;/li&gt;
&lt;/ul&gt;
&lt;p&gt;No mires sólo la CPU. Muchos chips de las placas de servidor dependen del flujo de aire del chasis. Si la velocidad del ventilador se reduce demasiado, es posible que la CPU aún se vea bien mientras el PCH, VRM o NIC se sobrecalienta.&lt;/p&gt;
&lt;h2 id=&#34;cambiar-la-velocidad-del-ventilador&#34;&gt;Cambiar la velocidad del ventilador
&lt;/h2&gt;&lt;p&gt;Los ventiladores de &lt;code&gt;HR650x&lt;/code&gt;/&lt;code&gt;HR630x&lt;/code&gt; se pueden controlar mediante comandos sin procesar de IPMI. El script comunitario utiliza este formato de comando:&lt;/p&gt;
&lt;div class=&#34;highlight&#34;&gt;&lt;div class=&#34;chroma&#34;&gt;
&lt;table class=&#34;lntable&#34;&gt;&lt;tr&gt;&lt;td class=&#34;lntd&#34;&gt;
&lt;pre tabindex=&#34;0&#34; class=&#34;chroma&#34;&gt;&lt;code&gt;&lt;span class=&#34;lnt&#34;&gt;1
&lt;/span&gt;&lt;/code&gt;&lt;/pre&gt;&lt;/td&gt;
&lt;td class=&#34;lntd&#34;&gt;
&lt;pre tabindex=&#34;0&#34; class=&#34;chroma&#34;&gt;&lt;code class=&#34;language-bash&#34; data-lang=&#34;bash&#34;&gt;&lt;span class=&#34;line&#34;&gt;&lt;span class=&#34;cl&#34;&gt;ipmitool -I lanplus -H &amp;lt;BMC_IP&amp;gt; -U &amp;lt;USER&amp;gt; -P &lt;span class=&#34;s1&#34;&gt;&amp;#39;&amp;lt;PASSWORD&amp;gt;&amp;#39;&lt;/span&gt; raw 0x2e 0x30 &lt;span class=&#34;m&#34;&gt;00&lt;/span&gt; &lt;span class=&#34;m&#34;&gt;00&lt;/span&gt; &amp;lt;SPEED&amp;gt;
&lt;/span&gt;&lt;/span&gt;&lt;/code&gt;&lt;/pre&gt;&lt;/td&gt;&lt;/tr&gt;&lt;/table&gt;
&lt;/div&gt;
&lt;/div&gt;&lt;p&gt;&lt;code&gt;&amp;lt;SPEED&amp;gt;&lt;/code&gt; se puede tratar como el porcentaje de ventilador objetivo. Por ejemplo:&lt;/p&gt;
&lt;div class=&#34;highlight&#34;&gt;&lt;div class=&#34;chroma&#34;&gt;
&lt;table class=&#34;lntable&#34;&gt;&lt;tr&gt;&lt;td class=&#34;lntd&#34;&gt;
&lt;pre tabindex=&#34;0&#34; class=&#34;chroma&#34;&gt;&lt;code&gt;&lt;span class=&#34;lnt&#34;&gt;1
&lt;/span&gt;&lt;span class=&#34;lnt&#34;&gt;2
&lt;/span&gt;&lt;span class=&#34;lnt&#34;&gt;3
&lt;/span&gt;&lt;span class=&#34;lnt&#34;&gt;4
&lt;/span&gt;&lt;span class=&#34;lnt&#34;&gt;5
&lt;/span&gt;&lt;span class=&#34;lnt&#34;&gt;6
&lt;/span&gt;&lt;span class=&#34;lnt&#34;&gt;7
&lt;/span&gt;&lt;span class=&#34;lnt&#34;&gt;8
&lt;/span&gt;&lt;/code&gt;&lt;/pre&gt;&lt;/td&gt;
&lt;td class=&#34;lntd&#34;&gt;
&lt;pre tabindex=&#34;0&#34; class=&#34;chroma&#34;&gt;&lt;code class=&#34;language-bash&#34; data-lang=&#34;bash&#34;&gt;&lt;span class=&#34;line&#34;&gt;&lt;span class=&#34;cl&#34;&gt;&lt;span class=&#34;c1&#34;&gt;# Set to 10%&lt;/span&gt;
&lt;/span&gt;&lt;/span&gt;&lt;span class=&#34;line&#34;&gt;&lt;span class=&#34;cl&#34;&gt;ipmitool -I lanplus -H 192.168.1.100 -U ADMIN -P &lt;span class=&#34;s1&#34;&gt;&amp;#39;password&amp;#39;&lt;/span&gt; raw 0x2e 0x30 &lt;span class=&#34;m&#34;&gt;00&lt;/span&gt; &lt;span class=&#34;m&#34;&gt;00&lt;/span&gt; &lt;span class=&#34;m&#34;&gt;10&lt;/span&gt;
&lt;/span&gt;&lt;/span&gt;&lt;span class=&#34;line&#34;&gt;&lt;span class=&#34;cl&#34;&gt;
&lt;/span&gt;&lt;/span&gt;&lt;span class=&#34;line&#34;&gt;&lt;span class=&#34;cl&#34;&gt;&lt;span class=&#34;c1&#34;&gt;# Set to 35%&lt;/span&gt;
&lt;/span&gt;&lt;/span&gt;&lt;span class=&#34;line&#34;&gt;&lt;span class=&#34;cl&#34;&gt;ipmitool -I lanplus -H 192.168.1.100 -U ADMIN -P &lt;span class=&#34;s1&#34;&gt;&amp;#39;password&amp;#39;&lt;/span&gt; raw 0x2e 0x30 &lt;span class=&#34;m&#34;&gt;00&lt;/span&gt; &lt;span class=&#34;m&#34;&gt;00&lt;/span&gt; &lt;span class=&#34;m&#34;&gt;35&lt;/span&gt;
&lt;/span&gt;&lt;/span&gt;&lt;span class=&#34;line&#34;&gt;&lt;span class=&#34;cl&#34;&gt;
&lt;/span&gt;&lt;/span&gt;&lt;span class=&#34;line&#34;&gt;&lt;span class=&#34;cl&#34;&gt;&lt;span class=&#34;c1&#34;&gt;# Set to 100%, useful for full-speed testing or thermal fallback&lt;/span&gt;
&lt;/span&gt;&lt;/span&gt;&lt;span class=&#34;line&#34;&gt;&lt;span class=&#34;cl&#34;&gt;ipmitool -I lanplus -H 192.168.1.100 -U ADMIN -P &lt;span class=&#34;s1&#34;&gt;&amp;#39;password&amp;#39;&lt;/span&gt; raw 0x2e 0x30 &lt;span class=&#34;m&#34;&gt;00&lt;/span&gt; &lt;span class=&#34;m&#34;&gt;00&lt;/span&gt; &lt;span class=&#34;m&#34;&gt;100&lt;/span&gt;
&lt;/span&gt;&lt;/span&gt;&lt;/code&gt;&lt;/pre&gt;&lt;/td&gt;&lt;/tr&gt;&lt;/table&gt;
&lt;/div&gt;
&lt;/div&gt;&lt;p&gt;Si ejecuta el comando desde el sistema operativo del servidor y los módulos del kernel IPMI están cargados, puede evitar la ruta de red BMC:&lt;/p&gt;
&lt;div class=&#34;highlight&#34;&gt;&lt;div class=&#34;chroma&#34;&gt;
&lt;table class=&#34;lntable&#34;&gt;&lt;tr&gt;&lt;td class=&#34;lntd&#34;&gt;
&lt;pre tabindex=&#34;0&#34; class=&#34;chroma&#34;&gt;&lt;code&gt;&lt;span class=&#34;lnt&#34;&gt;1
&lt;/span&gt;&lt;/code&gt;&lt;/pre&gt;&lt;/td&gt;
&lt;td class=&#34;lntd&#34;&gt;
&lt;pre tabindex=&#34;0&#34; class=&#34;chroma&#34;&gt;&lt;code class=&#34;language-bash&#34; data-lang=&#34;bash&#34;&gt;&lt;span class=&#34;line&#34;&gt;&lt;span class=&#34;cl&#34;&gt;ipmitool raw 0x2e 0x30 &lt;span class=&#34;m&#34;&gt;00&lt;/span&gt; &lt;span class=&#34;m&#34;&gt;00&lt;/span&gt; &lt;span class=&#34;m&#34;&gt;20&lt;/span&gt;
&lt;/span&gt;&lt;/span&gt;&lt;/code&gt;&lt;/pre&gt;&lt;/td&gt;&lt;/tr&gt;&lt;/table&gt;
&lt;/div&gt;
&lt;/div&gt;&lt;p&gt;Antes de cambiar la velocidad del ventilador, confirme que &lt;code&gt;ipmitool&lt;/code&gt; pueda leer los sensores:&lt;/p&gt;
&lt;div class=&#34;highlight&#34;&gt;&lt;div class=&#34;chroma&#34;&gt;
&lt;table class=&#34;lntable&#34;&gt;&lt;tr&gt;&lt;td class=&#34;lntd&#34;&gt;
&lt;pre tabindex=&#34;0&#34; class=&#34;chroma&#34;&gt;&lt;code&gt;&lt;span class=&#34;lnt&#34;&gt;1
&lt;/span&gt;&lt;span class=&#34;lnt&#34;&gt;2
&lt;/span&gt;&lt;/code&gt;&lt;/pre&gt;&lt;/td&gt;
&lt;td class=&#34;lntd&#34;&gt;
&lt;pre tabindex=&#34;0&#34; class=&#34;chroma&#34;&gt;&lt;code class=&#34;language-bash&#34; data-lang=&#34;bash&#34;&gt;&lt;span class=&#34;line&#34;&gt;&lt;span class=&#34;cl&#34;&gt;ipmitool -I lanplus -H &amp;lt;BMC_IP&amp;gt; -U &amp;lt;USER&amp;gt; -P &lt;span class=&#34;s1&#34;&gt;&amp;#39;&amp;lt;PASSWORD&amp;gt;&amp;#39;&lt;/span&gt; sensor
&lt;/span&gt;&lt;/span&gt;&lt;span class=&#34;line&#34;&gt;&lt;span class=&#34;cl&#34;&gt;ipmitool -I lanplus -H &amp;lt;BMC_IP&amp;gt; -U &amp;lt;USER&amp;gt; -P &lt;span class=&#34;s1&#34;&gt;&amp;#39;&amp;lt;PASSWORD&amp;gt;&amp;#39;&lt;/span&gt; sdr
&lt;/span&gt;&lt;/span&gt;&lt;/code&gt;&lt;/pre&gt;&lt;/td&gt;&lt;/tr&gt;&lt;/table&gt;
&lt;/div&gt;
&lt;/div&gt;&lt;p&gt;Si el &lt;code&gt;ipmitool&lt;/code&gt; local informa que no hay una interfaz utilizable, cargue estos módulos en Linux:&lt;/p&gt;
&lt;div class=&#34;highlight&#34;&gt;&lt;div class=&#34;chroma&#34;&gt;
&lt;table class=&#34;lntable&#34;&gt;&lt;tr&gt;&lt;td class=&#34;lntd&#34;&gt;
&lt;pre tabindex=&#34;0&#34; class=&#34;chroma&#34;&gt;&lt;code&gt;&lt;span class=&#34;lnt&#34;&gt;1
&lt;/span&gt;&lt;span class=&#34;lnt&#34;&gt;2
&lt;/span&gt;&lt;span class=&#34;lnt&#34;&gt;3
&lt;/span&gt;&lt;/code&gt;&lt;/pre&gt;&lt;/td&gt;
&lt;td class=&#34;lntd&#34;&gt;
&lt;pre tabindex=&#34;0&#34; class=&#34;chroma&#34;&gt;&lt;code class=&#34;language-bash&#34; data-lang=&#34;bash&#34;&gt;&lt;span class=&#34;line&#34;&gt;&lt;span class=&#34;cl&#34;&gt;modprobe ipmi_devintf
&lt;/span&gt;&lt;/span&gt;&lt;span class=&#34;line&#34;&gt;&lt;span class=&#34;cl&#34;&gt;modprobe ipmi_msghandler
&lt;/span&gt;&lt;/span&gt;&lt;span class=&#34;line&#34;&gt;&lt;span class=&#34;cl&#34;&gt;modprobe ipmi_si
&lt;/span&gt;&lt;/span&gt;&lt;/code&gt;&lt;/pre&gt;&lt;/td&gt;&lt;/tr&gt;&lt;/table&gt;
&lt;/div&gt;
&lt;/div&gt;&lt;p&gt;Un enfoque más seguro es no bloquear el ventilador a una velocidad muy baja, sino utilizar pasos basados ​​en la temperatura. Por ejemplo:&lt;/p&gt;
&lt;div class=&#34;highlight&#34;&gt;&lt;div class=&#34;chroma&#34;&gt;
&lt;table class=&#34;lntable&#34;&gt;&lt;tr&gt;&lt;td class=&#34;lntd&#34;&gt;
&lt;pre tabindex=&#34;0&#34; class=&#34;chroma&#34;&gt;&lt;code&gt;&lt;span class=&#34;lnt&#34;&gt;1
&lt;/span&gt;&lt;span class=&#34;lnt&#34;&gt;2
&lt;/span&gt;&lt;span class=&#34;lnt&#34;&gt;3
&lt;/span&gt;&lt;span class=&#34;lnt&#34;&gt;4
&lt;/span&gt;&lt;span class=&#34;lnt&#34;&gt;5
&lt;/span&gt;&lt;span class=&#34;lnt&#34;&gt;6
&lt;/span&gt;&lt;/code&gt;&lt;/pre&gt;&lt;/td&gt;
&lt;td class=&#34;lntd&#34;&gt;
&lt;pre tabindex=&#34;0&#34; class=&#34;chroma&#34;&gt;&lt;code class=&#34;language-text&#34; data-lang=&#34;text&#34;&gt;&lt;span class=&#34;line&#34;&gt;&lt;span class=&#34;cl&#34;&gt;CPU below 40°C: 10%
&lt;/span&gt;&lt;/span&gt;&lt;span class=&#34;line&#34;&gt;&lt;span class=&#34;cl&#34;&gt;CPU 40°C to 45°C: 14%
&lt;/span&gt;&lt;/span&gt;&lt;span class=&#34;line&#34;&gt;&lt;span class=&#34;cl&#34;&gt;CPU 45°C to 50°C: 20%
&lt;/span&gt;&lt;/span&gt;&lt;span class=&#34;line&#34;&gt;&lt;span class=&#34;cl&#34;&gt;CPU 50°C to 60°C: 50%
&lt;/span&gt;&lt;/span&gt;&lt;span class=&#34;line&#34;&gt;&lt;span class=&#34;cl&#34;&gt;CPU 60°C to 80°C: 80%
&lt;/span&gt;&lt;/span&gt;&lt;span class=&#34;line&#34;&gt;&lt;span class=&#34;cl&#34;&gt;CPU above 80°C: 100%
&lt;/span&gt;&lt;/span&gt;&lt;/code&gt;&lt;/pre&gt;&lt;/td&gt;&lt;/tr&gt;&lt;/table&gt;
&lt;/div&gt;
&lt;/div&gt;&lt;p&gt;Esto se puede implementar con Shell, Python o un temporizador systemd: lea la temperatura de la CPU cada pocos segundos y luego escriba el porcentaje de ventilador correspondiente. El script comunitario &lt;code&gt;HR650X-IPMI-Auto-Fan&lt;/code&gt; sigue esta idea.&lt;/p&gt;
&lt;p&gt;Para la sintonización manual, comience de manera conservadora. Pruebe primero con &amp;ldquo;20%&amp;rdquo; en inactivo, verifique que las temperaturas de CPU, PCH, VRM, memoria, NIC y PSU sean estables, luego intente gradualmente con &amp;ldquo;14%&amp;rdquo; o &amp;ldquo;10%&amp;rdquo;. Para pruebas de carga completa, no comience con velocidades bajas del ventilador; comience en &amp;ldquo;50%&amp;rdquo; o más, confirme el espacio libre de enfriamiento y luego encuentre un equilibrio entre ruido y temperatura.&lt;/p&gt;
&lt;p&gt;Los comandos sin procesar de IPMI son comandos OEM del proveedor y el comportamiento puede diferir entre las versiones de firmware de BMC. Antes de ponerlos en funcionamiento, asegúrese de que la máquina pueda leer los sensores normalmente y tenga un terminal listo para volver a poner los ventiladores en alta velocidad. Si las lecturas de temperatura son anormales, los sensores muestran &amp;ldquo;na&amp;rdquo; o la velocidad del ventilador no cambia como se esperaba, no continúe bajando la velocidad.&lt;/p&gt;
&lt;h2 id=&#34;fuentes-de-alimentación-placas-verticales-placas-posteriores-y-bandejas-de-unidades&#34;&gt;Fuentes de alimentación, placas verticales, placas posteriores y bandejas de unidades
&lt;/h2&gt;&lt;p&gt;Un gran problema del &amp;ldquo;HR650x&amp;rdquo; es que la interfaz de la fuente de alimentación y muchas piezas de expansión no son piezas estándar de PC. La fuente de alimentación utiliza un factor de forma específico de Lenovo, por lo que reemplazar o agregar una puede resultar costoso.
Compruebe también las contrahuellas con antelación. Los distintos paneles verticales admiten distintos diseños de tarjetas, como de altura completa y de longitud completa, de altura completa y de media longitud y de media altura y de media longitud. Si planea instalar GPU, HBA, NIC 25G/40G o adaptadores NVMe más adelante, confirme el tipo de elevador antes de comprar la máquina.&lt;/p&gt;
&lt;p&gt;Los backplanes de unidades también tienen múltiples configuraciones. Es posible que vea placas posteriores de bahías de 2U.2, 4U.2, 8U.2 o 2,5 pulgadas. Los backplanes, los cables, las bandejas, las tarjetas RAID o los HBA pueden generar costos adicionales.&lt;/p&gt;
&lt;p&gt;Una sugerencia práctica: si desea que la máquina sólo arranque y ejecute tareas informáticas, no se apresure a completar cada bandeja y backplane. Si su objetivo es el almacenamiento totalmente flash o una alta expansión, incluya esas partes en el presupuesto total desde el principio.&lt;/p&gt;
&lt;h2 id=&#34;bmc-bios-y-administración&#34;&gt;BMC, BIOS y administración
&lt;/h2&gt;&lt;p&gt;Las máquinas retiradas de la nube a menudo vienen con contraseñas BMC desconocidas. Si puede ingresar al BIOS, generalmente puede crear o restablecer un usuario de administración allí. Si puede iniciar un sistema operativo, &lt;code&gt;ipmitool&lt;/code&gt; también puede administrar usuarios de BMC.&lt;/p&gt;
&lt;p&gt;Generalmente es mejor actualizar BIOS y BMC a una versión estable más nueva, por tres razones:&lt;/p&gt;
&lt;ul&gt;
&lt;li&gt;Soporte para más modelos Xeon de segunda generación.&lt;/li&gt;
&lt;li&gt;Mejor detección y gestión de Optane PMem.&lt;/li&gt;
&lt;li&gt;Correcciones para BMC, política de fans o problemas de compatibilidad de hardware.&lt;/li&gt;
&lt;/ul&gt;
&lt;p&gt;Las referencias mencionan que &lt;code&gt;HR630x&lt;/code&gt;/&lt;code&gt;HR650x&lt;/code&gt; pueden requerir actualizaciones de BIOS para &lt;code&gt;8259CL&lt;/code&gt; y Optane. Los distintos lotes de máquinas varían: algunos vendedores ya las han actualizado, mientras que otros requieren trabajo manual.&lt;/p&gt;
&lt;p&gt;Las descargas de BIOS y BMC para &lt;code&gt;HR650x&lt;/code&gt; se pueden encontrar a través de la página de soporte de Lenovo:&lt;/p&gt;
&lt;div class=&#34;highlight&#34;&gt;&lt;div class=&#34;chroma&#34;&gt;
&lt;table class=&#34;lntable&#34;&gt;&lt;tr&gt;&lt;td class=&#34;lntd&#34;&gt;
&lt;pre tabindex=&#34;0&#34; class=&#34;chroma&#34;&gt;&lt;code&gt;&lt;span class=&#34;lnt&#34;&gt;1
&lt;/span&gt;&lt;/code&gt;&lt;/pre&gt;&lt;/td&gt;
&lt;td class=&#34;lntd&#34;&gt;
&lt;pre tabindex=&#34;0&#34; class=&#34;chroma&#34;&gt;&lt;code class=&#34;language-text&#34; data-lang=&#34;text&#34;&gt;&lt;span class=&#34;line&#34;&gt;&lt;span class=&#34;cl&#34;&gt;https://datacentersupport.lenovo.com/cn/zc/products/servers/thinksystem-hyperscale/hr650x/7x57/7x57cto1ww/j300cvx2/downloads/driver-list/
&lt;/span&gt;&lt;/span&gt;&lt;/code&gt;&lt;/pre&gt;&lt;/td&gt;&lt;/tr&gt;&lt;/table&gt;
&lt;/div&gt;
&lt;/div&gt;&lt;p&gt;Además, &lt;code&gt;HR650x&lt;/code&gt; admite decodificación superior a 4G, pero la compatibilidad con BAR de tamaño variable no es ideal. Si planea instalar GPU con VRAM grande o usar la máquina para computación GPU, primero confirme las opciones del BIOS y los planes del cable de alimentación.&lt;/p&gt;
&lt;h2 id=&#34;quién-debería-probar-esto&#34;&gt;¿Quién debería probar esto?
&lt;/h2&gt;&lt;p&gt;Este tipo de máquina es más adecuada para personas que:&lt;/p&gt;
&lt;ul&gt;
&lt;li&gt;Necesita muchos subprocesos x86 baratos.&lt;/li&gt;
&lt;li&gt;Puede tolerar el consumo de energía en inactivo y el ruido.&lt;/li&gt;
&lt;li&gt;Contar con espacio para servidores en rack.&lt;/li&gt;
&lt;li&gt;Están dispuestos a leer manuales, inspeccionar etiquetas de tableros y utilizar un multímetro.&lt;/li&gt;
&lt;li&gt;Puede aceptar incertidumbre en partes de servidores usados.&lt;/li&gt;
&lt;li&gt;Tenga paciencia para solucionar problemas de IPMI, BIOS, VRM y DCPMM.&lt;/li&gt;
&lt;/ul&gt;
&lt;p&gt;Es menos adecuado para personas que:&lt;/p&gt;
&lt;ul&gt;
&lt;li&gt;Sólo quiero un NAS silencioso.&lt;/li&gt;
&lt;li&gt;Quiere un mini servidor de bajo consumo 24 horas al día, 7 días a la semana.&lt;/li&gt;
&lt;li&gt;No quiero tratar con BMC, ventiladores, elevadores, placas posteriores o fuentes de alimentación patentadas.&lt;/li&gt;
&lt;li&gt;No tener CPU de repuesto, memoria de repuesto ni herramientas de depuración básicas.&lt;/li&gt;
&lt;li&gt;No se pueden aceptar actualizaciones de BIOS, modificaciones de VRM ni ajustes de ventiladores después de la compra.&lt;/li&gt;
&lt;/ul&gt;
&lt;h2 id=&#34;resumen&#34;&gt;Resumen
&lt;/h2&gt;&lt;p&gt;El principal valor de &lt;code&gt;HR630x&lt;/code&gt;/&lt;code&gt;HR650x&lt;/code&gt; es que proporcionan una plataforma de servidor de doble socket LGA3647 de bajo costo. Con Xeons económicos de segunda generación como &lt;code&gt;8259CL&lt;/code&gt; y Optane PMem, pueden convertirse en nodos de computación de laboratorio doméstico con un número de subprocesos, capacidad de memoria y administración remota impresionantes.&lt;/p&gt;
&lt;p&gt;Los problemas son igual de claros: es posible que las CPU OEM de alta potencia no sean compatibles de forma predeterminada, por lo que puede ser necesaria una modificación del VRM &lt;code&gt;MCP2221A&lt;/code&gt;; se deben verificar las versiones y la compatibilidad de las ranuras de memoria; el ruido del ventilador y la energía inactiva no pueden tratarse como hardware de consumo; Los soportes verticales, las placas posteriores, las bandejas de unidades y las fuentes de alimentación pueden aumentar los costos.&lt;/p&gt;
&lt;p&gt;Si el presupuesto es ajustado y te gusta trastear, esta es una ruta interesante. Si desea algo estable, silencioso y de bajo mantenimiento, calcule la potencia total, el ruido, las piezas incluidas y el costo de mantenimiento futuro antes de comenzar.&lt;/p&gt;
&lt;h2 id=&#34;referencias&#34;&gt;Referencias
&lt;/h2&gt;&lt;ul&gt;
&lt;li&gt;lyc8503: AIO Ep19. Registro de compilación del servidor Lenovo HR630x (HR650x): &lt;a class=&#34;link&#34; href=&#34;https://blog.lyc8503.net/post/19-first-rack-server-hr630x/&#34;  target=&#34;_blank&#34; rel=&#34;noopener&#34;
    &gt;https://blog.lyc8503.net/post/19-first-rack-server-hr630x/&lt;/a&gt;&lt;/li&gt;
&lt;li&gt;一只白泽_沧渊: Notas de solución de problemas de HR650x, fuente: bilibili: &lt;a class=&#34;link&#34; href=&#34;https://www.bilibili.com/read/cv36922131/?opus_fallback=1&#34;  target=&#34;_blank&#34; rel=&#34;noopener&#34;
    &gt;https://www.bilibili.com/read/cv36922131/?opus_fallback=1&lt;/a&gt;&lt;/li&gt;
&lt;li&gt;Vision0220: HR650X-IPMI-Auto-Fan: &lt;a class=&#34;link&#34; href=&#34;https://github.com/Vision0220/HR650X-IPMI-Auto-Fan&#34;  target=&#34;_blank&#34; rel=&#34;noopener&#34;
    &gt;https://github.com/Vision0220/HR650X-IPMI-Auto-Fan&lt;/a&gt;&lt;/li&gt;
&lt;li&gt;Página de soporte oficial de Lenovo HR630x: &lt;a class=&#34;link&#34; href=&#34;https://datacentersupport.lenovo.com/us/en/products/servers/thinksystem-hyperscale/hr630x&#34;  target=&#34;_blank&#34; rel=&#34;noopener&#34;
    &gt;https://datacentersupport.lenovo.com/us/en/products/servers/thinksystem-hyperscale/hr630x&lt;/a&gt;&lt;/li&gt;
&lt;li&gt;Página de soporte oficial de Lenovo HR650x: &lt;a class=&#34;link&#34; href=&#34;https://datacentersupport.lenovo.com/cn/zc/products/servers/thinksystem-hyperscale/hr650x&#34;  target=&#34;_blank&#34; rel=&#34;noopener&#34;
    &gt;https://datacentersupport.lenovo.com/cn/zc/products/servers/thinksystem-hyperscale/hr650x&lt;/a&gt;&lt;/li&gt;
&lt;li&gt;Página de descarga de BIOS/BMC de Lenovo HR650x: &lt;a class=&#34;link&#34; href=&#34;https://datacentersupport.lenovo.com/cn/zc/products/servers/thinksystem-hyperscale/hr650x/7x57/7x57cto1ww/j300cvx2/downloads/driver-list/&#34;  target=&#34;_blank&#34; rel=&#34;noopener&#34;
    &gt;https://datacentersupport.lenovo.com/cn/zc/products/servers/thinksystem-hyperscale/hr650x/7x57/7x57cto1ww/j300cvx2/downloads/driver-list/&lt;/a&gt;&lt;/li&gt;
&lt;li&gt;Orden de instalación del DIMM Lenovo SR650 para modo independiente: &lt;a class=&#34;link&#34; href=&#34;https://pubs.lenovo.com/sr650/zh-CN/dimm_installation_dram_independent_mode_2&#34;  target=&#34;_blank&#34; rel=&#34;noopener&#34;
    &gt;https://pubs.lenovo.com/sr650/zh-CN/dimm_installation_dram_independent_mode_2&lt;/a&gt;&lt;/li&gt;
&lt;/ul&gt;